Did a Windstorm knock off the Ducks’ Barn?

One (1) section of a barn (hereinafter referred to as Barn X) used for rearing ducks was reported to have collapsed.

1 min read

One (1) section of a barn (hereinafter referred to as Barn X) used for rearing ducks was reported to have collapsed. Prior to the alleged incident, the weather near the premises was reported to be windy and drizzling but no heavy rain.

Agi forensic investigation windstorm damage investigation figure
Agi forensic investigation windstorm damage investigation figure
Figure 4: Columns below the floor of Barn X that depict additional ‘L’-shaped lumber members (red arrows) installed adjacent to the existing main columns with concrete bases (yellow arrows).
Figure 5: Panoramic view shows severe slanting of columns (red arrows), ‘L’-shaped lumber member (yellow arrow) affixed adjacent to the existing columns, and diagonally-placed lumber supports (blue arrow) which are anchored.
Figures 6: The lumber column located at (C2, R3) had shifted and the fractured section shows white paint on the surfaces of the dimensionally-reduced region (red arrow), just above the fractured end. Wood debris (yellow arrow) was found within the anchor point of the concrete base.
Figures 7: Close-up views of the tubular-shaped voids with green mould around the base end (left) and rotten fractured end (right), located at (C1, R1).
Agi forensic investigation windstorm damage investigation figure

Based on the assessment of the structural integrity and historical weather, the failure of the structure of Barn X was not caused by the alleged windstorm incident.

Barn X had sustained progressive organic consumption and weathering throughout the years, partially collapsed as triggered by the movement of the ducks within the barn. The lack of more supporting columns along the north of the partially-collapsed section to offset the concentration of stress also portrayed an important role to the structural failure.

The destruction, radical conversion, or disappearance of a building material by any one of a variety of processes or organisms that consume the material, including fire, termites, beetles, worms, enzymes, rodents, fungi, microbial corrosion, decay, and bacterial fermentation.

Degradation due to exposure to the weather.

Keep reading

Related insights

All insights
  • Figure 1: Overview of the Boiler Room.

    Case StudyForensic Investigation

    Boiler Explosion Investigation

    The director of a lumber core manufacturing plant was in his office when he suddenly heard an explosion-like sound coming from the Boiler Room in the production…

    By AGI Team2 min read
    Read the case study
  • Figure 1: Allegedly damaged components of the screw compressor

    Case StudyForensic Investigation

    Failure investigation of a Chiller and an Extruder

    A chiller and an extruder were reported to have failed in a plastic pipe and container manufacturing company. The incident was discovered by the supervisor…

    By AGI Team3 min read
    Read the case study
  • Front view of the MAC. The red arrow indicates the location of the MAC.

    ArticleForensic Investigation

    Compressor Failed. WHY?

    A Second Stage Compressor (SSC) failed at an air collection company. Prior to the incident, a power failure occurred on the same day at 1700 hours which caused…

    By AGI Team1 min read
    Read the article

24/7 response

Does this affect a claim you are handling?

Send us the detail and we will tell you what a proper investigation would need to establish.