Approved Group International
Agi steam turbine failure investigation the damage sustained to the exhaust valve that broke apart from the force of the explosion
All insights

Steam Turbine Failure Investigation

At about 0930 hours on Monday, 13 January 2014, an explosion occurred at a steam turbine generator.

1 min read

At about 0930 hours on Monday, 13 January 2014, an explosion occurred at a steam turbine generator.

The incident occurred as the operator was about to start the affected machine at the beginning of the day. When the pressure at boiler, internally known as ‘Boiler No. 1’, reached 31 bar, the operator prepared to start up the turbine. He opened the inlet valve gradually for steam to enter the turbine from the boiler. As the turbine reached approximately 300 revolutions per minute (RPM), he heard a sudden loud bang which resulted in a cloud of smoke and steam being released along with metal debris flying around the area.

Agi steam turbine failure investigation view of the exhaust pipe that was dislodged during the incident

The investigation was conducted through a site visit to inspect the affected machinery, data gathering, damage analysis and scientific interpretation of the physical evidence. Interviews were also conducted with several eye-witnesses and relevant personnel to gather information surrounding the incident. Following the damage analysis of the affected steam turbine generator, the physical evidence, an examination of the provided photographs, and the gathered witness statements, it is the Approved Forensics Team’s finding that the failure originated due to an operator error, who did not open the exhaust valve when he commenced operations of the steam turbine generator.

Agi steam turbine failure investigation view of the expansion joint and exhaust pipe which had bent backwards
Agi steam turbine failure investigation view of the fragments belonging to the exhaust valve that had broken off with the force of the explosion

Keep reading

Related insights

All insights
  • Agi failure of a kiln burner at a cement plant view of the kiln burner

    ArticleForensic Investigation

    Failure of a Kiln Burner at a Cement Plant

    The operation for Kiln 3 at a cement plant was stopped at 11.25pm due to red spot (brick failure). Investigation indicates that the air channel pipe was…

    By AGI Team2 min read
    Read the article
  • Agi crane failure investigation visual examination of sample a

    Case StudyForensic Investigation

    Crane Failure Investigation

    At approximately 0840 hours on Thursday, 1 August 2013, it was reported that hoist crane No ‘2’ had fallen after hoisting a set of screws.

    By AGI Team1 min read
    Read the case study

24/7 response

Does this affect a claim you are handling?

Send us the detail and we will tell you what a proper investigation would need to establish.